7. Technical data .................16 8. Maintenance and service ............18 8.1. Self diagnostics ................18 8.1.1. Fibre optic receiver LED ..........18 8.1.2. RS232 LED ..............18 8.1.3. Service LED ..............18 8.1.4. Service and spare parts ...........18 9. Ordering information ..............19 Appendix A ................20 ABB Automation...
The SLTA option card also contains a fibre-optic transceiver pair of one of the following types: - ST-type glass fibre-optic transceiver - snap-in-type plastic fibre-optic transceiver The transceiver types are not interchangeable and have to be specified in the order. For ordering information, see chapter 9. ABB Automation...
ORKS Other user definable parameters are: - automatic communication speed detection - user definable communication speeds are 1200, 2400, 9600, 14400, 19200, 38400, 57600 and 115200 bits per second. ABB Automation...
LTS-20 core module The Echelon LTS-20 core module contains the core electronics and firmware required to implement an SLTA. In addition, the LTS-20 core module contains parameters required for the communication to the L network (address information, etc.). ORKS ABB Automation...
160 mm. The size of the front plate is 116.4 mm x 19.8 mm. SSLTA-C-MM RS232 interface Service Service LED Service Service pin RS232 LED RS232 Fibre optic TX Fibre optic LED Configuration jumpers Fibre optic RX sslta_3 )LJ 0HFKDQLFDO VWUXFWXUH RI WKH 6/7$ RSWLRQ FDUG ABB Automation...
D-type connector, which has to be made of conductive material. The connector of the option card is earthed to the case of the RER 111 unit. The figure 5.2.1.-1 illustrates the connection of the protective shield to the cable connector. ABB Automation...
DCD OUT DCD IN DTR IN DTR OUT DSR IN DSR OUT RTS IN RTS OUT CTS OUT CTS IN RIOUT RIIN sslta_6 9 pin female 9 pin male D-connector D-connector )LJ 'LDJUDP IRU DQ ZLUH FRQQHFWLRQ ABB Automation...
SLTA option card. When the switch is pressed and released, the SLTA generates a service pin message. The service pin message is sent to the L network, NOT to the RS232 interface. ORKS ABB Automation...
If a modem is to be used in conjunction with the SLTA option card, the jumpers must be set for DTE mode. In any other case, the jumpers must be set for DCE. Factory default setting: DCE mode. ABB Automation...
J5 specifies the type of interface, i.e.3-wire or 8-wire, to be used with the RS232 connection. The 3-wire interface uses the TXD, RXD and GND signals of the RS232 serial interface. The 8-wire interface is used with a modem. Factory default setting: 3-wire interface. ABB Automation...
EEPROM memory in LTS-20 core module and incorrect settings may cause severe damage to the LTS-20 core module or even destroy it completely. 1RWH Refer to Echelon for more information. ® LTS-20 LonTalk Serial Adapter User’s Guide. Manual No: 078-0181-01A ABB Automation...
Electrostatic discharge test according to IEC 61000-4-2 and IEC 60255-22-2, class III - contact discharge 6 kV - air discharge 8 kV Environmental conditions ° Specified ambient service temperature range -10...+55 ° Transport and storage temperature range -40...+70 ABB Automation...
Page 17
SLTA Option Card 1MRS 750107-MUM Technical Reference Manual Climatic environmental tests Dry heat test according to IEC 60068-2-2 +55°C Dry cold test according to IEC 60068-2-1 -10°C Damp heat test according to IEC 60068-2-30 RH = 93%, 55°C, 6 cycles ABB Automation...
If the service LED is continuously on, then the network interface has detected a hardware failure. 8.1.4. Service and spare parts If a fault occurs in the SLTA option card, the faulty option card should be replaced with a new one. For ordering information see chapter 9. ABB Automation...
The RS232 cable to be used between a SRIO 1000M and the SLTA option card can be ordered separately. The type designation of the cable is: 2QH VHULDO FRPPXQLFDWLRQ FDEOH EHWZHHQ 65,2 0 1 pcSPA-ZP 23A3 DQG 6/7$ RSWLRQ FDUG 7KH OHQJWK RI WKH FDEOH LV PHWUHV Number of cables ABB Automation...
App buf out size App buf in size Net buf out size Net buf in size Net buf priority count App buf priority count App buf out count App buf in count Net buf out count Net buf in count ABB Automation...
Page 21
Update version (Q4/99) 01.03.2000 M. Kiikkala References to SMA-transceiver option removed Echelon, LON, LonBuilder, LonManager, LonTalk, LonWorks, Neuron and 3150 are U.S. registered trademarks of Echelon Corporation. LonLink, LonMark, LonSupport, LonUsers, LonMaker and 3120 are trademarks of Echelon Corporation. ABB Automation...