Advertisement

3.
Attach the brackets to the PSU sides of the chassis using four screws for each bracket. Attach the
bracket so that the "ear" is parallel to the PSU and the outside of the chassis.
Figure 6. Attaching the Mounting Brackets into a Four-Post Rack or Cabinet
1.
View from the chassis I/O side
3.
Screws
5.
Connect to the rack or cabinet (ears)
4.
Attach the long bracket to each side of the chassis using the provided countersink screws. Use two
screws on each side of the chassis.
5.
Install the rack mount ears into the I/O-facing posts using rack mount screws (not included with the
system).
NOTE: Mount the rack mount ears so that the system is level when fully installed.
6.
Using the provided pan head screws, attach the rack ears on the I/O facing posts to the long bracket
(attached to the system). To secure, tighten the pan head screws.

Installing the System into a Four-Post Rack or Cabinet

To install a system into a four-post equipment rack using the already attached mounting brackets, follow
these steps.
1.
Ensure that there is adequate clearance surrounding the rack or within the cabinet to permit access
and airflow.
2.
Install the system into the rack. Ensure the long brackets dock into the previously installed rack ears.
18
2.
Connect to the rack or cabinet
4.
Screws
6.
Power Supply
Install the S4810–ON