Toshiba e-STUDIO203 Service Handbook page 66

Hide thumbs Also See for e-STUDIO203:
Table of Contents

Advertisement

Classifi-
Code
cation
483
Laser
Pre-running rotation of
polygonal motor
486
Laser
Timing of auto-clearing of
polygonal motor pre-run-
ning rotation
502
Image
Error diffusion and dither
setting at photo mode
515
Fuser
Temperature setting of
warming-up
(Center thermistor)
516
Fuser
Temperature setting of
warming-up
(Side thermistor)
e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE
Setting mode (08)
Func-
Items
tion
ALL
ALL
PPC
ALL
ALL
2 - 46
06/05
Default
<Accept-
RAM
able
value>
0
SYS
Sets whether or not
<0-2>
switching the polygonal
motor from the standby
rotation to the normal
rotation when the origi-
nal is set on the ADF or
the platen cover is
opened.
0: Valid (when using
ADF and the origi-
nal is set manually)
1: Invalid
2: Valid (when using
ADF only)
0
SYS
Switches the polygonal
<0-2>
motor to the standby
rotation when a certain
period of time has
passed from the pre-
running. At this code,
the period to switch the
status to the standby
rotation is set.
0: 15 sec.1: 30 sec.
2: 45 sec.
*
This setting is effec-
tive when "0" or "2"
is set at 08-483.
1
SYS
Sets the image repro-
<0-1>
duction method at
photo mode.
0: Error diffusion
1: Dither
9
M
0: 140°C 1: 145°C
<0-14>
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
9
M
0: 140°C 1: 145°C
<0-14>
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
Proce-
Contents
dure
1
1
1
1
1
December 2005 © TOSHIBA TEC