3.3

Image Quality Adjustment (Copying Function)

3.3.1
Density adjustment
The center density and the density variation controlled by density adjustment keys can be adjusted as
follows.
Original mode
Text/Photo
Photo
503
501
505
506
508
509
514
512
Make a test copy and compare the image obtained with the current settings; if necessary, make adjust-
ment using the following procedure.
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Key in a code and press the [START] button.
(3)
Key in an adjustment value.
(To correct the keyed-in value, press the [CLEAR] button.)
Press the [INTERRUPT] button to store the value. Æ The equipment goes back to the ready
(4)
state.
(5)
Let the equipment restarted and perform copying job.
(6)
If the desired image density has not been attained, repeat step (2) to (5).
December 2005 © TOSHIBA TEC
Item to be adjusted
Text
504
Manual density mode center
value
507
Manual density mode light
step value
510
Manual density mode dark
step value
515
Automatic density mode
3 - 19
< Adjustment Mode (05) >
Remarks
The larger the value is, the darker the
image becomes.
Acceptable values: 0 to 255
The larger the value is, the lighter the
light side becomes.
Acceptable values: 0 to 255
The larger the value is, the darker the
dark side becomes.
Acceptable values: 0 to 255
The larger the value is, the darker the
image becomes.
Acceptable values: 0 to 255
e-STUDIO163/203 ADJUSTMENT