Craftsman 82315 Owner's Manual page 10

Mini multimeter with non-contact voltage detector (ncv)
Table of Contents

Advertisement

NOTES:
Accuracy specifications consist of two elements:
• (% reading) – This is the accuracy of the measurement circuit.
• (+ digits) – This is the accuracy of the analog to digital
Accuracy is stated at 65
Diode Test
Continuity Check
Temperature Sensor
Input Impedance
AC Bandwidth
Display
Overrange indication
Auto Power Off
Polarity
Measurement Rate
Low Battery Indication
Battery
Fuses
Operating Temperature
Storage Temperature
Operating Humidity
converter.
o
F to 83
75% RH.
Test current: 0.3mA max., Open
circuit voltage: 1.5V DC typ.
Audible signal will sound if the
resistance is less than 100!
Requires type K thermocouple
10M! (VDC & VAC)
50 / 60Hz
4000 count (0 to 3999 digits) backlit
LCD
For all functions "OL" is displayed
(Note: For ACV measurements only,
an audible beep will also sound)
After 15 minutes (approximately) of
inactivity
No indication for positive; Minus (-)
sign for negative
2 times per second, nominal
"
is critically low
Two (2) 1.5V 'AAA' batteries
mA, "A ranges: 500mA/250V fast
blow;
'A' range: 10A/250V fast blow
32ºF to 122ºF (0ºC to 50ºC)
-4
<70% RH
o
o
o
F (18
C to 28
" is displayed if battery voltage
o
o
F to 140
F (-20
10
C) and less than
o
o
C to 60
C)

Advertisement

Table of Contents
loading