Fault Descriptions - Bosch ICP-SOL2-P User Manual

Hide thumbs Also See for ICP-SOL2-P:
Table of Contents

Advertisement

20
en | Operation with ICON LCD Codepad
Fault Indicators
Zone
Indicator
1
2
3
4
5
6
7
8
Table 5.4: Fault Indicators
5.6.1

Fault Descriptions

1 System Fault
A system fault only displays when any of the following faults occur. After entering Fault
Analysis Mode, press and hold the [1] key to determine which of the following faults occurred.
Low Battery Fault – A low battery fault registers when the system detects a low capacity
back-up battery. The system automatically performs a battery test every four hours and every
time you arm the system.
Date and Time – The date and time fault registers every time the system is powered down.
Refer to Date and Time, page 21 to program the date and time.
RF Receiver Fail – The RF receiver fault registers once the system detects that the wireless
receiver unit is disconnected, tampered or jammed.
Output 1 to 3 Fail – This fault registers when the system detects any output is disconnected.
This fault clears once any output is reconnected. Your installer must program the system for
this feature to operate.
Telephone Line Fail – A telephone line fault registers when the system detects that the
telephone line is disconnected from the control panel. Your installer must program the system
for this feature to operate.
Power Supply Fail – This fault occurs when AUX power supplies fails, +12V power fails, or
SDI2 Bus power fails. Contact your installer as soon as this fault displays.
Tamper – This fault occurs when the system detects the control panel is tampered.
2014.05 | 01 | F01U298028
Fault Description
Hold Down
Button
System Fault
1
RF Low Battery
2
Zone Tamper Alarm
3
Sensor Watch Fault
4
RF Sensor Watch
5
Communication Fail 6
Output and
7
Codepad Fail
Keyfob Low Battery
8
User's Guide
Zone
Fault Condition
Indicator
1
Battery Fail
2
Date and Time
3
RF Receiver Fail
4
Output 1 to 3 Fail
5
Telephone Line Fail
7
Power Supply Fail
8
Tamper
9
RF Repeater Fail
1 to 16
Zones 1 to 16 RF Low Battery
1 to 16
Zones 1 to 16 Tamper Alarm
1 to 16
Zones 1 to 16 Sensor Watch Fail
1 to 16
Zones 1 to 16 RF Sensor Watch Fail
1
Receiver 1 Fail
2
Receiver 2 Fail
3
IP Module 1 Fail
4
IP Module 2 Fail
2
Output Expander Fail
3 to 6
Codepad Fail
1
Keyfob Low Battery
Control Panel