Electrical Adjustments
4. Auto calibration adjustment [Component]
Input mode
Computer 1 (Component)
Input signal
480i component signal
Signal pattern
8 color bar
1. Enter the service mode
260
2. Select Group "
", No. "
0
1
. After the auto-calibration com
value from "
" to "
"
, "OK" will appear on the screen.
pleted
Below adjustments are performed when the above auto
calibration is failed.
Pedestal adjustment [Component]
Input signal
480i component signal
Signal pattern
16-step gray scale
Equipment
Oscilloscope
1. Enter the service mode.
2. Adjust the black level on each test point to be minimum
by changing the data value of Group - No.
Group - No.
Test Points
0 - 0
TP35G
0 - 1
TP35R
0 - 2
TP35B
Gain adjustment [Component]
1. Enter the service mode.
2. Adjust the amplitude "
to be minimum by changing the data value of Group -
No.
Group - No.
Test Points
0 - 3
TP35G
White Level
(a)
0
" and then change data
a
" of waveform at each test point
5. Auto calibration adjustment [Video]
Input mode
Input signal
Signal pattern
1. Enter the service mode.
260
2. Select Group "
0
value from "
" to "
"OK"
pleted,
will appear on the screen.
Below adjustment is performed when the above auto
calibration is failed.
Gain adjustment [Video]
Equipment
1. Enter the service mode.
2. Adjust the amplitude "
to be minimum by changing the data value of Group -
No.
Group - No.
Test Points
20 - 0
TP35G
(a)
-38-
Video
Composite video signal
16-step gray scale
0
", No. "
" and then change data
1
". After the auto-calibration com-
Oscilloscope
a
" of waveform at each test point
White Level