Panasonic PT-TW230U Service Manual page 52

Hide thumbs Also See for PT-TW230U:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
10 Temp Error Cooling Time
OnStart Cooling Start
11
Threshold
12 After shutdown cooling
Group
Fan Lamp Voltage Lower Setting
256
0 Lamp Voltage
1 Lamp Voltage Threshold
2 Fan1 Speed Gain
3 Fan2 Speed Gain
4 Fan3 Speed Gain
Group
Fan Dimmer Setting
257
Dimmer Average Check
0
Period
1 Dimmer Average
2 Last Voltage Difference
3 Voltate Difference Goal
Group
Auto Calibration (Commn) * Auto Calibration
260
0 Execute Calibration
1 Loop Count
2 Auto Status
3 AutoWait
4 CHECK -Tolelance
Group
Auto Calibration (RGB)
261
0 OFFSET AREA H START
1 OFFSET AREA V START
2 GAIN AREA H START
3 GAIN AREA V START
4 Image AREA H WIDTH
5 Image AREA V HIGHT
6 OFFSET target
7 OFFSET torelance
8 GAIN target
9 GAIN torelance
Group
Auto Calibration (CVBS/SVIDEO)
262
0 Y Image Area Start X
1 Y Image Area Start Y
6 Image Area H Width
7 Image Area V Hight
8 Y Target Level
11 Gain Tolerance
12 Delta Gain
Group
Auto Calibration (YCbCr)
264
0 Y-OFFSET AREA H START
1 Y-OFFSET AREA V START
CB - OFFSET AREA H
2
START
3 CB - OFFSET AREA V START CB - Offset Acquiring Area V-Start
4 CR - OFFSET AREA H
START
5 CR - OFFSET AREA V START
6 Y - GAIN AREA H START
7 Y - GAIN AREA V START
8 CB - GAIN AREA H START
Function
Cooling Time setting at Temp Er-
ror (x 30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling after shutdown (0: No, 1:
Yes)
Current-voltage lamp (unit: 0.1V)
(Read only)
V × 10 unit threshold is deter-
mined that the lamp voltage
drops
Min Fan voltage plus the amount
of time the lamp voltage drops
(unit: 0.1V)
Avarage Time to Measurement
0: 10 sec, 1:30 sec, 2: 60 sec, 3: 90
sec. ....
Average Dimmer
Last Voltage Dfference (x0.1V)
Target Voltage Difference (0.1V)
Executes Auto-Calibration when
changing the Value to 1 (PC White
100%)
Maximum Execution Times (OFFSET-
>GAIN)
Result of Auto-Calibration (Last
Memory)
Wait Value for each setting
Torelance of OFFSET
Black Level Acquiring Area H-Start
Position
Black Level Acquiring Area V-Start
Position
White Level Acquiring Area H-Start
Position
White Level Acquiring Area V-Start
Position
Black/White Level Acquiring Area
Black/White Level Acquiring Area
Height
Target Value of Black Level Adj.
Torelance of Black Level Adj.
Target Value of White Level Adj.
Torelance of White Level Adj.
Y Acquiring Area H-Start Position
Y Acquiring Area V-Start Position
Image Level Acquiring Area
Image Level Acquiring Area Height
Target Value of Y Level Adj.
Torelance of Level Adj.
Deviation Width of Gain Value
Y - Offset Acquiring Area H-Start
Position
Y - Offset Acquiring Area V-Start
Position
CB - Offset Acquiring Area H-Start
Position
Position
CR - Offset Acquiring Area H-Start
Position
CR - Offset Acquiring Area V-Start
Position
Y
Initial
3
38
1
-
0
10
10
10
1
-
-
-
0
10
0
1
2
975
500
25
500
13
9
3
1
238
1
20
200
8
9
217
1
9
925
500
925
500
925
500
50
500
800
-52-
Range
Note
1-15
0-100
0-1
0-255
30-90
0-255
0-255
0-255
0-10
-
-
-
0 - 1
1 - 30
0 / 1 / 9
0: OK, 1: Adjusting,2: Error * ReadOnly
1 - 20
1 - 255
0 - 1000
0 - 1000
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 127
1 - 127
0 - 255
1 - 255
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 255
0 - 255
0 - 255
0 - 1000
0 - 1000
0 - 1000
If not used: use Y's value
0 - 1000
If not used: use Y's value
0 - 1000
If not used: use Y's value
0 - 1000
If not used: use Y's value
0 - 1000
0 - 1000
0 - 1000

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-tw231ruPt-tw231rePt-tw231reaPt-tw230ePt-tw230ea

Table of Contents