Electrical Adjustments
Group/
Item Name
Item
5 DIMMER_CTRL_
LEVEL6
DIMMER_CTRL_
6
LEVEL7
DIMMER_CTRL_
7
LEVEL8
8 DIMMER_CTRL_
LEVEL9
9 DIMMER_CTRL_
LEVEL10
DIMMER_CTRL_
LEVEL11
11 DIMMER_CTRL_
LEVEL12
12 DIMMER_CTRL_
LEVEL13
DIMMER_CTRL_
13
LEVEL14
14 DIMMER_CTRL_
LEVEL15
DIMMER_AVERAGE_
15
POINT
DIMMER_AVERAGE_
16
DATA
17 DIMMER_LEVEL_AUTO Current Dimmer Leverl
18 DIMMER_LEVEL_
NORMAL
19 DIMMER_LEVEL_ECO
20 Panel life mode
21 VOLTAGE_LEVEL
22 DIMMER_LEVEL_HIGH
Group
VBI Slice Level
230
0 Generic Initial Slicing
Level
1 Generic High Level
Threshold
2 Generic Low Level
Threshold
3 Generic Minimum Low
Level
4 Generic Maximum High
Level
Group
FAN Control * Fan volltage adjustment
250
0 FAN1
MIN
ADJUST
(DAC)
1 FAN1
MAX
ADJUST
(DAC)
2 FAN2
MIN
ADJUST
(DAC)
3 FAN2
MAX
ADJUST
(DAC)
4 FAN3
MIN
ADJUST
(DAC)
5 FAN4
MAX
ADJUST
(DAC)
Group
Fan Option
252
0 HI-LAND SWITCH
1 SAFETY Switch
2 FAN MANUAL SWITCH
FAN1 MANUAL VOLT-
3
AGE
FAN2 MANUAL VOLT-
4
AGE
FAN3 MANUAL VOLT-
5
AGE
Function
Level-6 data for dimming
brightness: when less than the
dimming level 6
Level-7 data for dimming
brightness: when less than the
dimming level 7
Level-8 data for dimming
brightness: when less than the
dimming level 8
Level-9 data for dimming
brightness: when less than the
dimming level 9
Level-10 data for dimming
brightness: when less than the
dimming level 10
Level-11 data for dimming
brightness: when less than the
dimming level 11
Level-12 data for dimming
brightness: when less than the
dimming level 12
Level-13 data for dimming
brightness: when less than the
dimming level 13
Level-14 data for dimming
brightness: when less than the
dimming level 14
Level-15 data for dimming
brightness: when less than the
dimming level 15
Luminance Data Avarage Point
for Mimmer
Luminance Data Avarage Value
for Dimmer
Normal Dimmer Level
Eco Dimmer Level
Panel life mode
Lamp Voltage
PW190 register 0xE344
PW190 register 0xE345
PW190 register 0xE346
PW190 register 0xE347
PW190 register 0xE348
DAC Output for Fan
Adjust the tolerance of DAC
and Fan Volage.
* Lamp mode is forced Eco
0: Normal, 1: Hi-Land , 2-4:
Hi-Land "1-3"
For test purpose
0: Auto, 1: Manual
Fan Voltage (unit : 0.1V)
Effective only when Fan
Manual switch is 1
Initial
42
49
56
63
70
77
84
91
98
105
4
-
-
15
0
0
-
15
9
0
0
0
255
28
205
36
207
30
235
0
0
0
100
100
100
-50-
Range
Note
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
1 - 16
-
* Read only
-
* Read only
0 - 15
0 - 15
0 - 1
-
Unit: 8bit(Raw Data) * Read only
0 - 15
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0 - 2
* Read only
0.3 - 6
0 - 3
0 - 255