Write Protect Sensor Check Or Adjustment; Head Load Check - NEC FD1165 Maintenance Manual

Flexible disk drive
Hide thumbs Also See for FD1165:
Table of Contents

Advertisement

5.5.3
Write Protect Sensor Check or Adjustment
After
the
wr i te protect
sensor
is
replaced,
perform
the
following check.
a.
Insert
a
flexible
disk
that
has
a
write
protect
notch into the disk drive.
b.
Check that the voltage at TPII is less than 0.5 V.
Move the jacket of the flexible disk to make sure
that the voltage at TPII does not change.
c.
If
the
voltage
changes,
loosen
the
screw
that
fastens
the sensor and change the posi tion of the
sensor until the vol tage does not change when the
flexible disk is moved.
d.
Remove the flexible disk and insert a disk without
a write protect notch.
e.
Check tha t
the vol tage at TPII is more than 3.3 V.
Move the jacket and make sure that the voltage does
not change.
f.
If the vol tage changes, change the posi tion of the
sensor until tbe vol tage does not change when the
jacket is moved.
5.5.4
Head Load Check
Perform
this
check
after
replacemen t
procedures
are
per-
formed.
a.
Write data of alIOs to an assigned track (using the
drive tester).
b.
Load the heads and look at the read waveform.
c.
If the unstable area of the waveform is not within
the specifications shown in Figure 5-8, replace the
carriage assembly.