Kenwood CK 408/1 Instructions For Use - Installation Advice page 34

Double oven ceramic cooker
Table of Contents

Advertisement

CONNECTION OF THE POWER
SUPPLY CABLE
Connecting the power cord must be
entrusted to skilled personnel in accor-
dance with the instructions supplied
by the manufacturer and in compliance
with established safety standards.
To connect the feeder cable to the cooker it
is necessary to:
Remove the two screws that hold
shield "A" behind the cooker (fig. 10.1).
Open completely the cable clamp "D" .
Fitted with a 6-pole terminal block, po-
sition the U bolts onto terminal block
'B' (fig. 10.1) according to the dia-
grams in figs. 10.2 - 10.3.
Feed the supply cable through the ca-
ble clamp "D" . The supply cable must
be of a suitable size for the current re-
quirements of the appliance; see the
section "Feeder cable section" .
Connect the phase, neutral and earth
wires to terminal "B" according to figu-
res 10 .2 and 10 .3 .
Pull the feeder cable and block it with
the cable clamp "D" .
Re-mount shield "A" .
NOTE: Earth cable must be 3 cm longer
than neutral and live cables .
34
FEEDER CABLE SECTION
TYPE H05RR-F or H05VV-F
230 V ac
400 V 3N ac
400 V 2N ac
(**) Connection with wall box connection .
Diversity factor applied .
A diversity factor may be applied to the
total loading of the appliance only by a
suitably qualified person.
D
Fig. 10.1
3 x 6 mm
(**)
2
5 x 2,5 mm
(**)
2
4 x 4 mm
(**)
2
B
A