Traction (Flow Divider) Manifold Service - Toro Groundsmaster 4000-D Service Manual

Hide thumbs Also See for Groundsmaster 4000-D:
Table of Contents

Advertisement

Traction (Flow Divider) Manifold Service

50 ft- -lb
(67 N- -m)
20 ft- -lb
(27 N- -m)
198 in- -lb
(22.4 N- -m)
10
20 ft- -lb
(27 N- -m)
5
198 in- -lb
(22.4 N- -m)
20 ft- -lb
(27 N- -m)
40 ft- -lb
(54 N- -m)
1. Flow divider valve
2. Piloted directional valve
3. Orifice (0.020)
4. Traction manifold
NOTE: The ports on the manifold are marked for easy
identification of components. Example: P2 is the gear
pump connection port and CD is the connection for the
case drain from the deck motors (See Hydraulic Sche-
matic in Chapter 9 -- Foldout Drawings to identify the
function of the hydraulic lines and cartridge valves at
each port).
Hydraulic System
1
5
10
5
6
Figure 62
5. Check valve
6. Plug with O- -ring (SAE #8)
7. Solenoid coil
Page 4 - - 90
50 ft- -lb
(67 N- -m)
2
4
40 ft- -lb
(54 N- -m)
6
3
10
8. Nut
9. Solenoid cartridge valve
10. Plug with O- -ring (SAE #6)
Groundsmaster 4000--D
FRONT
UP
20 ft- -lb
(27 N- -m)
5 ft- -lb
(6.7 N- -m)
9
7
8
198 in- -lb
(22.4 N- -m)

Hide quick links:

Advertisement

Table of Contents
loading