5.7
2 - 26
Relay Contact Rating: 500 mA, 24 Vdc
5.6.8

SMDR Output

Female Connector (LAN) Standard DB-9 (straight)
5.6.9

PC Connection

Female Connector (LAN) Standard DB-9 (straight)
5.6.10

Relay Contact

All Relay Contact Ratings: 500 mA, 24Vdc

Battery Backup

The UNIVERGE SV9100 system has battery backup functions for system
backup and for memory backup.
5.7.1

System Backup (Optional)

During a power failure, the system can be backed up using the
CHS2UG BATT MTG KIT for a backup time of 10 minutes or one of
the CHSG LARGE BATT SETs for a backup time ranging from
45~180 minutes.
5.7.2

Memory Backup

The GCD-CP10 Blade battery retains the Clock/Calender and Last
Number redial (LNR) buffers for each station when the GCD-CP10
Blade encounters a power loss. With a fully charged battery, the
settings are retained for about three years. The System Programmed
memory (Customer Database) is stored in non-volatile Memory and
can be erased only by a First Initialization. After power is restored,
the system Blade returns to normal operation.