Sanyo SFX-11 Service Manual page 31

Hide thumbs Also See for SFX-11:
Table of Contents

Advertisement

3.
4.
.—
5.
Press -]
twice.
Press ~.
Press w]
to memorize the wave for a shading signal
L
ISCAN
TEST
?
\
I**
SCAN
TEST
*I
Return to Stand-by
The RAM CODE can also be accessed by key-in op?ration without setting up to the test mode as follows
1. Press m
4 times.
SET
MODE
?
(P
ROGRAMMIERUNG)
2. Press ~.
O.T
DIAL
SET
(Z. w.)
3. Press m
4 times.
FEATURE
SW
SET
(SW
SC HALT)
4. Press ~
while pressing down m
key.
Sw
m
CODE
Now the
RAM CODE can be accessed.
' ~
d) MODEM TEST
1. Wing
up to the test mode.
(Refer to 6-3-(l))
TEST
MODE
?
2. Press ~.
INITIAL
SET
?
3. Press-1
three(3) times.
MODEM
TEST
?
4. Press ~.
9600
BPS
(0)
Press m]
to appear the next signal.
Press m]
to appear the previous signal.
9600BPS(0) +
7200BPS(0) +
4800BPS(0) +
2400BPS(0) +
300BPS(0) +
L+
2100HZ +
1100HZ +
PB 8 +
NO SIGNAL +
Return to the 1st stage (9600BPS(0))
The signals 9600,7200,4800,2400
and 300BPS can be changed its carrier frequency pattern as shown below.
Press -1
to change its pattern at each stage.
L
(o)
:
1850HZ continuously
(1)
:
1650HZ continuously
(1:1):
1650/1 850 alternately (3.3msec/3.3msec)
(1:4)
:
1650/1850 alternately (3.3msec/13.2msec)
1
time is a case of 300BPS.
(4:1)
:
1650/1850 alternately (13.2msec/3.3msec)
—29—