7.
Configure your (a) subnet mask and (b) gateway address if needed.
(a) Type asmc2 -kcs 30 01 01 05
encoded in hexadecimal system)
(b) Type asmc2 -kcs 30 01 01 0C
encoded in hexadecimal system)
Refer to Appendix if you have trouble converting your subnet mask/gateway
address to hexadecimal value representation.
8.
Type asmc2 -init_asmb to effect the configuration.
9.
Type asmc2 -bmc_info on the prompt, then press <Enter> to display the BMC
and PET IP and MAC addresses.
Firmware Version : 1.01 (DSBF-D/SAS, DSBF-D, DSBV-D, DSCC-D12/SAS, DSCC-D12,
DSCC-DW
BMC IP
: 10.10.10.10
BMC MAC : 00 E0 18 51 10 7A
PET IP
: 00.00.00.00
PET MAC : 00 00 00 00 00 00
SOL BAUD: 57600
10. Restart the remote server, enter the BIOS setup, then boot from the hard disk
drive.
11. Configure the ASMB3-SOL PLUS baud rate (asmc2 -sol_baud 57600).
Make sure that the ASMB3-SOL PLUS baud rate is the same as the Remote
Access baud rate that you previously set in the BIOS. See section 2.4 BIOS
remote console for details.
12. Adjust the local/central server network settings, if necessary.
ASUS ASMB3-SOL PLUS
(your subnet mask
FF FF FF 00
(your gateway address
0A 0A 0A FE