Toro Greensmaster 3150 Service Manual page 107

Hide thumbs Also See for Greensmaster 3150:
Table of Contents

Advertisement

IMPORTANT: Avoid using excessive clamping
pressure on the motor flange to prevent distorting
the casting.
3. Clamp mounting flange of motor in a vise with the
shaft end down.
4. Loosen cap screws on the rear cover.
5. Take motor from the vise and remove cap screws.
6. Remove front flange from the body, then remove rear
cover. Locate and remove dowel pins from body.
IMPORTANT: Mark the relative positions of the gear
teeth and the bearing blocks so they can be re-
assembled in the same position. Do not touch the
gear surfaces as residue on hands may be corrosive
to gear finish.
7. Place the motor on its side and push on the rear bear-
ing block to remove the bearing block and gear set
(Fig. 59).
8. Carefully remove and discard O--rings, pressure
seals and back--up rings (Fig. 60) from motor. Do not
cause any damage to the machined grooves during the
removal process.
IMPORTANT: Make sure to not damage the counter
bore when removing the shaft seal from the front
plate.
9. Position front flange with seal side up. Remove shaft
seal.
Inspection
1. Remove any nicks and burrs from all motor compo-
nents with emery cloth.
CAUTION
Use eye protection such as goggles when using
compressed air.
2. Clean all motor components with solvent. Dry all
parts with compressed air.
Greensmaster 3150
1
2
1. Motor body
2
3
1. Drive gear
2. Idler gear
Page 4 - - 79
Figure 59
2. Bearing block & gear set
Figure 60
1
3
Figure 61
3. Bearing block