Connect the cable connector to the CNRF terminal on the control board. Switch ON SW1-8.
Check the maximum reach of the cable to
install the bracket with screws.
Do not excessively pull the cable when
measuring the maximum reach.
<Notice>
● Do not overtighten the screws.
►The bracket may deform or break.
● When installing the bracket, select an interference-free space.
►Keep the installing area at least 10 cm away from metal or a wall box. If unable to do
so, always place the wireless remote controllers in locations where the communication
test determines that the wireless remote controllers are fully capable of communica-
tion with the wireless receiver.
● Do not install the bracket with screws on the exterior casing of the hydrobox unit.
►The internal parts may become damaged, which could result in breakdown of the in-
door unit.
When installing the wireless receiver,
observe the following.
● Keep the other electric or electronic
devices (e.g. radio, induction cooker, mi-
crowave, and refrigerator, mobile phone
or the like) at least 50 cm away from the
wireless receiver.
● As much as possible, place the wireless
receiver in an interference-free area and
keep the wireless receiver away from
metal.