77
Info.
The cache was initialized as a result of power up or failover.
Recommended actions
No action is required.
78
Warning
The controller could not use an assigned spare for a vdisk because the spare's capacity is too small.
This occurs when a disk in the vdisk fails, there is no dedicated spare available and all global spares are
too small or; if the dynamic spares feature is enabled, all global spares and available disks are too small.
Recommended actions
Replace existing spares or add spares with enough capacity to replace the smallest disk in the vdisk.
The vdisk size is limited by its disk with the least capacity.
79
Info.
A trust operation has completed for the indicated vdisk.
Recommended actions
Be sure to complete the trust procedure as documented in the CLI help for the trust command.
80
Info.
The controller enabled or disabled the indicated parameters for one or more disks.
Recommended actions
No action is required.
81
Info.
The current controller has unkilled the partner controller. The other controller will restart.
Recommended actions
No action is required.
83
Info.
The partner controller is changing state (shutting down or restarting).
Recommended actions
No action is required.
84
Warning
The current controller that logged this event forced the partner controller to fail over.
Recommended actions
See "Resources for diagnosing and resolving problems" in the SMU help for the System Events panel,
or the CLI help for the show events command.
86
Info.
Host-port or disk-channel parameters have been changed.
Recommended actions
No action is required.