87
Warning
The mirrored configuration retrieved by this controller from the partner controller has a bad cyclic
redundancy check (CRC). The local flash configuration will be used instead.
Recommended actions
•
Restore the default configuration by using the restore defaults command, as described in the CLI
Reference Guide.
88
Warning
The mirrored configuration retrieved by this controller from the partner controller is corrupt. The local flash
configuration will be used instead.
Recommended actions
•
Restore the default configuration by using the restore defaults command, as described in the CLI
Reference Guide.
89
Warning
The mirrored configuration retrieved by this controller from the partner controller has a configuration level
that is too high for the firmware in this controller to process. The local flash configuration will be used
instead.
Recommended actions
•
The current controller that logged this event probably has down-level firmware. Update the firmware on
the down-level controller. Both controllers should have the same firmware versions.
When the problem is resolved, event 20 is logged.
90
Info.
The partner controller does not have a mirrored configuration image for the current controller, so the current
controller's local flash configuration is being used.
This event is expected if the other controller is new or its configuration has been changed.
Recommended actions
•
No action is required.
91
Error
In a testing environment, the diagnostic that checks hardware reset signals between controllers in
Active-Active mode failed.
Recommended actions
•
Perform failure analysis.
95
Error
Both controllers in an Active-Active configuration have the same serial number. Non-unique serial numbers
can cause system problems; for example, vdisk ownership and WWNs are determined by serial number.
Recommended actions
•
Remove one of the controller modules and insert a replacement, then return the removed module to be
reprogrammed.
HP P2000 G3 MSA System Event Descriptions Reference Guide
19