Wiring Diagram-Wgfm195 - Whirlpool WGFM195 Installation Instructions Manual

Hide thumbs Also See for WGFM195:
Table of Contents

Advertisement

NOTES:
1. Set heat anticipator on room thermostat at 0.7 amps.
2. Manufacturer's specified replacement parts must be used
when servicing.
3. If any of the original wire as supplied with the furnace must be
replaced, it must be replaced with wiring material having a
temperature rating of at least 105ºC. Use copper conductors
only.
Disconnect ALL power before servicing.
Multiple power sources may be present.
Failure to do so may cause property damage, personal injury or death.
Equipment GND
Field GND
Field Splice
Switch (Temperature)
Igniter
Pressure Switch
Overcurrent
Prot. Device
Low Voltage (24V)
Low Voltage Field
High Voltage (115V)
High Voltage Field
Junction
Terminal
Internal To
Integrated Control
Plug Connection
Color
Symbol
Gray:
GY
White:
W
Black:
BK
Red:
R
Blue:
BU
Orange:
OR
Yellow:
Y
Green:
G
Pink:
PK
Azure:
A
Violet:
V
Brown:
BR
Steady On =
Normal Operation
Off =
Control Failure
1 Flash =
System Lockout (Retries Exceeded)
2 Flashes =
Pressure Switch Stuck Closed
3 Flashes =
Pressure Switch Stuck Open
4 Flashes =
Open High Limit Switch
5 Flashes =
Flame Sense without Gas Control Valve
6 Flashes =
Open Rollout Limit Switch or Open Fuse
7 Flashes =
Low Flame Signal
8 Flashes =
Check Igniter or Improper Grounding
Continuous/
Rapid Flashes =
Reversed 115 VAC Polarity
Wiring is subject to change.
Always refer to the wiring
diagram on the unit for the
most up-to-date wiring.
Check codes for proper wiring and circuit protection before installation.
46
WIRING DIAGRAM—WGFM195
WARNING
HIGH VOLTAGE!
24 VAC
OR
Humidifier
24 VAC
40 VA
Transformer
24V Thermostat
115 VAC
Connections
C
G
R
W
Y
W
BK
Fuse
3
Integrated
Control
6
Module
9
ON OFF
12 11 10
2nd
Stage
Delay*
GY
Mode*
Heat
Off
OR
Delay*
*Factory Settings Shown
FS
See
Diagnostic LED
Note 6.
115 VAC Hot and Park Terminals
COOL-H
HEAT-H
LINE-H
See
GND
Note 4.
W
BK (HI)
R
BU (MED)
OR(MED LOW)
R (LOW)
BK
Circulator Blower
BR
BR
Capacitor
Blower Compartment
Burner Compartment
GND
BK
W
Induced Draft Blower
Auto Reset
Primary Limit
Control
Y
R
OR
N O
C
W
Manual Reset Rollout Limit (Control(s)
Induced Draft
(Single Control On 45 kBtu)
24 VAC
Blower Pressure
Humidifier
Switch
C
1
2-Circuit
PM
GY
Connector
Hot
C
2
BR
Surface
Igniter
HI
3
Gas Control Valve
4. If heating and cooling blower speeds are not the same,
discard jumper before connecting blower leads. Unused
blower leads must be placed on "PARK" terminals of
integrated control or taped.
5. Furnace must be permanently grounded and conform to NEC
and local codes.
6. To recall the last 5 faults, most recent to least recent, depress
switch for more than 2 seconds in standby (no thermostat
inputs).
GY
OR
GY
2
1
PK
5
4
OR
8
7
BU
G
Y
OR
OR
BR
R
GY
W
2
W
1
BK
PK
Y
PR
W
W
PR
BU
OR
R
PK
BU
Front Cover
Pressure Switch
NO
GY
GND
G
OR
TR(6)
GND
GND(8)
C
MVC(9)
HI
MVH(12)
PM
C
MVL(2)
NO
C
G
NO
PS(10)
C
PSO(4)
Y
HLI(7)
W
HLO(1)
R
RO2(11)
RO1(5)
TH(3)
24 VAC
115 VAC
XFMR-H
FS
IGN
IND
COOL-H
EAC-H
LINE-H
GND
N
L
N
W
GND
BK
L