Kenwood DDX6034 Service Manual page 20

Hide thumbs Also See for DDX6034:
Table of Contents

Advertisement

DDX6034/6034M/6054/7034BT/7034BTM/714
DNX7000EX/7140/7240BT/7340BT
Key Specifi cation
q
: Flicker Adjustment. (The topmost part is MIN
and the lowermost part is MAX.)
Touching an arbitrary part sets a preset value
according to the places.
w
: Transfer to the LCD Adjustment screen. (Cancel)
e
: Start the Writing-in operation in the nonvolatile
memory. (Next)
Return : Transfer to the LCD Adjustment screen.
* Select black for the background color until "Write OK/NG"
is displayed.
Modify the background color to blue at the same time as
"Write OK" is displayed.
Modify the background color to red at the same time as
"Write NG" is displayed.
2.3.13. X35 Power Frequency Check screen
This screen is used to perform switching of the inverter and
the DC/DC frequency.
Power Frequency Check screen is displayed in Figure 2.3.13.
X35 Power Frequency Check
Inverter
DC/DC
Figure 2.3.13 Power Frequency Check screen
Key Specifi cation
Inverter Low : Set the Inverter Frequency to a Low level.
Inverter High : Set the Inverter Frequency to a High level.
DC/DC Low : Set the DC/DC Frequency to a Low level.
DC/DC High : Set the DC/DC Frequency to a High level.
Return
: Transfer to Test Mode Main screen.
20
TEST MODE
Low
High
Low
High
Return
2.3.14. Tilt Mecha Adjustment screen
This screen is used to perform adjustment of the Panel
Mechanism.
The Tilt Mecha Adjustment screen is displayed in Figure
2.3.14.
Tilt Mecha Adjust
Mecha Adjust
Cancel
Figure 2.3.14 Tilt Mecha Adjustment screen
Key Specifi cation
Mecha Adjust : Start adjustment of the Panel Mecha-
nism.
Cancel
: Transfer to Test Mode Main screen.
Return
: Transfer to Test Mode Main screen.
* Select black for the background color until "Write OK/NG"
is displayed.
Modify the background color to blue at the same time as
"Write OK" is displayed.
Modify the background color to red at the same time as
"Write NG" is displayed.
The "NG" is displayed when the status is in any one of the
following conditions: (When the "NG" is displayed, no data
is written in the nonvolatile memory.)
Failure in writing data in nonvolatile memory
When the voltage acquired is 0.268V or higher in the
Open condition
When the voltage acquired is lower than 4.160V or it is
higher than 4.376V in the Close condition
Note: In case of "NG", check if the mechanism position ad-
justment jig is properly installed or not, and then transfer to
the Test mode again to start over the adjustment.