Kenwood DDX6034 Service Manual page 61

Hide thumbs Also See for DDX6034:
Table of Contents

Advertisement

CC
8
ND
A
5.0V
5.0V
2.5V
-9.0V
B
+9V
6
J200
4
IC100-102
3
RELAY
: NJM4565V-ZB
CORD
2
RL2
IC103 : ICL7660SIBAZ
1
RL1
GND
(X29-449x-xx)
DESTI-
MODEL NAME
NATION
DNX7140
DNX7000EX
DNX7340BT
DNX7240BT
DDX714
DDX7034BT
DDX7034BTM
M2
DNX9140
DDX814
DDX8034BT
DDX8034BTM
DNX9240BT
DDX8024BT
DDX8054BT
DDX6034
DDX6034M
M4
DDX6054
CD
CN100
14
R132
0
+9V
IC102
1
8
9.0V
V+
7
5.0V
2
3
6
5.0V
4
5
2.5V
V-
9V
R146 22K
R141 22K
C128
C125
1000P
1000P
Q107
Q105
Q106
Q4,6,100,102-105,107
Q110,112,114,116,201,
:
DTC143TUA
204,205,207,210,211
Q5,101,106
: DTA144EUA
Q111,113,115,203,209
Q108
: UMC2N
Q109,202,208
Q200,206
: 2SB1443
UNIT
C2,
D2,7-9,11,
A D
B
C
33-35,37,127,128
No.
7-9
310-312
K1
K2
X1
E1
0-12
YES
YES
K
M1
K
K
M
M
0-13
YES
YES
YES
YES
E
E
Q
X2
0-21
YES
Q1
CE
PRE OUT
13
12
11
10
9
8
7
6
5
+9V
5V AMP
IC101
5.0V
1
8
9.0V
V+
7
5.0V
5.0V
2
2.5V
3
6
5.0V
-9.0V
4
5
2.5V
V-
9V
R129 22K
R125 22K
C118
C116
1000P
1000P
Q104
Q103
PRE MUTE
BU5V
D1-3,18 : STZ6.2N
D4,6,7,9
:
UDZW6.8(B)
: 2SC4081
D5,8
:
UDZW6.2(B)
D10-13 : AVRM16270MAAB
: 2SA1576A
D14,15,100-105
: AVRM16180M6AB
: DTC114TUA
R5,12,21,31,
R132
YES
YES
YES
• DC voltages are as measured with a high impedance volt me-
ter. Val ues may vary slight ly due to vari a tions between in di-
vid u al in stru ments or/and units.
CF
DDX6034/6034M/6054/7034BT/7034BTM/714
DNX7000EX/7140/7240BT/7340BT
4
3
2
1
ESDGND
+9V
IC100
5.0V
1
8
9.0V
V+
7
5.0V
5.0V
2
2.5V
3
6
5.0V
-9.0V
4
5
2.5V
V-
R109 22K
R106 22K
C108
C107
1000P
1000P
Q102
Q100
Q101
DDX6034/6034M/6054/7034BT/7034BTM/714
DNX7000EX/7140/7240BT/7340BT (3/5)
D16,17,106-110
: DAP202U
D111
: UDZW11(B)
D112
:
UDZW5.6(B)
D200-203 : 1SR154-400
D307-312 : CVS10A120M
CAUTION : For continued safety,
re place safe ty critical com po nents
only with manufacturer's rec om-
mend ed parts (refer to parts list).
VIDEO LINE
Indicates safety critical com-
SIGNAL LINE
po nents. To reduce the risk of
GND LINE
B LINE
electric shock, leakage-cur rent
B LINE
or re sis tance mea sure ments shall
be carried out (ex posed parts are
ac cept ably in su lat ed from the sup-
ply cir cuit) be fore the ap pli ance is
returned to the customer.
X29-4490-xx (2/2)