Belt Maintenance; Checking The Alternator Belt; Controls System Maintenance; Adjusting The Control Lever Neutral Interlock Switch - Toro 30695 Operator's Manual

Traction unit
Hide thumbs Also See for 30695:
Table of Contents

Advertisement

Belt Maintenance

Checking the Alternator Belt

Service Interval: Every 100 hours
Check the condition and tension of the belts
every 100 operating hours.
1. Proper tension will allow 10 mm (3/8 inch) deflection
when a force of 44 N (10 lb.) is applied on the belt
midway between the pulleys.
2. If the deflection is not 10 mm (3/8 inch), loosen the
alternator mounting bolts
decrease the alternator belt tension and tighten the
bolts. Check the deflection of the belt again to ensure
that the tension is correct.
g020537
Figure 43
1. Mounting bolt
(Figure
43) after
(Figure
43). Increase or
1
2
2. Alternator
Controls System
Maintenance
Adjusting the Control Lever
Neutral Interlock Switch
1. Stop the machine, move the deck lift switch fully into
the neutral-locked position, set the parking brake, and
remove the ignition key.
2. Remove the bolts securing the front panel and remove
the panel
(Figure
2
1
1. Bolts
2. Control panel
3. Loosen the 2 screws securing the interlock switch
(Figure
45).
42
44).
G020875
Figure 44