Stop the operation of a PCI module using the ft server utility.
3.
Move to the directory where the NEC ESMPRO Agent is installed.
# cd /opt/nec/esmpro_sa/bin
Start the ft server utility.
# ./ESMftcutil
The screen of the ft server utility will appear.
Select [ftServer] - [PCI Module] - [PCI Module (to be removed)]. The screen of the PCI
Module(to be removed) will appear.
Select [PCI Module Start/Stop] - [Stop] to the stop of the PCI .Module.
* As for the primary PCI module (*), if the PCI module 0 is primary select [PCI
Module(ID:10)]. If the PCI module 1 is primary, select [PCI Module (ID:11)].
When you stop the operation of the primary PCI module, a failover occurs and the
secondary PCI module becomes the primary module.
ft server utility
Linux Setup and Operation 3-13
PCI Module