3-16 Linux Setup and Operation
ft server utility
Restart the CPU module.
3.
In the ft server utility, select the stopped CPU module and click [Start] of [CPU Module
Start/Stop].
Once the CPU module is started, hardware diagnosis and then synchronization of memory
(memory copy) are performed, and the duplication process is completed.
Note that the system is paused temporarily for copying memory during memory
synchronization.
[Indications of status LEDs after completion of duplication]
1
PRIMARY LED
2
DISK ACCESS LED
3
System FT LED
IMPORTANT:
After duplication is completed, the FT LED illuminates in green.
Do not perform the evaluation of start and stop unless the above process is completed.
LED
LED
CPU Module
Secondary
(Operating)
(Operating)
Green
Green
System
Green
Primary
-
Green