Misfeed in the transport area, fusing area, and exit area

Transport area
1
Open the upper side cover and check for a
misfeed.
NOTE
If paper is loaded in the bypass tray, remove the paper
and close the bypass tray before opening the side cover.
NOTE
The misfeed may have occurred inside the machine.
Check carefully and remove it.
Gently close the upper side cover.
2
NOTE
Even after clearing a misfeed, paper may remain inside
the machine on the transfer belt where it is not visible. In
this case, after visible misfeeds are removed, the paper
on the transfer belt will be automatically moved to a
position where it is visible and a misfeed will be indicated
once again on the display. Clear the misfeed as explained
in "Misfeed in the transfer unit" (step 3 on the right side of
this page). For this reason, it may be necessary to
perform the "Misfeed in the transfer unit" procedure twice.
Exit area
1
Misfeed in the exit area
Push the blue lever
upward and gently open
the cover.
Be careful not to tear the
misfed
paper
during
removal.
Models with an exit tray
attached to the duplex
bypass/inverter unit:
Gently remove the misfed
paper as shown in the
illustration, taking care
not to tear the paper.
Models
without
the
duplex bypass/inverter
unit:
Gently remove the misfed
paper as shown in the
illustration, taking care
not to tear the paper.
Centre exit tray:
Gently
remove
the
misfed paper as shown
in the illustration, taking
care not to tear the
paper.
Fusing area
1
Open the duplex bypass/inverter unit.
2
Remove the misfed paper as shown in the
illustrations below.
CAUTION
The fusing unit is hot. Take care in removing paper. (Do
not touch any metal parts.)
CAUTION
The fusing unit is hot. Take care in removing paper. (Do not
touch any metal parts.)
3
Misfeed in the transfer unit
CAUTION
The transfer unit is hot. Take care in removing paper. (Do
not touch any metal parts.)
4
Gently close the duplex bypass/inverter unit.
MISFEED REMOVAL
Grasp the finger hold
and gently open the unit.
If paper is misfed in the
transport area, turn roller
knob A in the direction of
the arrow to remove the
misfed paper.
If you do not find a
misfeed, open the cover
of the fusing unit and
check for a misfeed
inside the fusing unit.
If paper is misfed on the
transfer belt, remove it
gently without touching
the transfer belt. Do not
pull out the transfer unit.
After closing, confirm that
the
misfeed
message
has been cleared and the
normal display appears.
If
the
duplex
bypass/inverter unit is not
installed, close the side
cover in the same way.