5.4 MODBUS(R)/TCP Equipment Setting
For details of the MODBUS
5.5 Device Range that Can Be Set
The device ranges of controller that can be used for GOT are as follows.
Note that the device ranges in the following tables are the maximum values that can be set in GT Designer3.
The device specifications of controllers may differ depending on the models, even though belonging to the same series.
Please make the setting according to the specifications of the controller actually used.
When a non-existent device or a device number outside the range is set, other objects with correct device settings may
not be monitored.
Setting item
Item
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of word device.
Device
File No.
Information
Displays the device type and setting range which are selected in [Device].
Set the station number of the controller to be monitored.
Host
Network
Other
®
/TCP equipment, refer to the manual of MODBUS
Set the file No.
The file No. can be set only when select 6 at [Device].
Select this item for monitoring the host controller.
Select this for monitoring other controllers.
After selecting the item, set the station number and network number of the controller to be monitored.
NW No.:
For the MODBUS
For the MODBUS
Station No.: Set the station No.
®
/RTU equipment to be used.
Description
®
/RTU connection, set "1".
®
/TCP connection, set the network No.
5. MODBUS(R)/TCP CONNECTION
5.4 MODBUS(R)/TCP Equipment Setting
5
5 - 7