RAS-10BKV-E / RAS-10BAV-E
RAS-13BKV-E / RAS-13BAV-E
P
Pressure measurement
Gauge attaching port
Vacuum pump connecting port
Deoxidized copper pipe
Outer dia. : 9.52mm
Thickness : 0.8mm
4-way valve
TS
Temp. measurement
INDOOR UNIT
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
Outer dia. : 6.35mm
Thickness : 0.8mm
Sectional shape
of heat insulator
Muffler
Muffler
TD
Compressor
NX89F0F-20D
Outdoor heat
exchanger
T2
Propeller fan
OUTDOOR UNIT
- 21 -
FILE NO. SVM-16003
T1
Temp. measurement
TC
TA
Strainer
Pulse Modulating
valve at liquid side
Strainer
TO
TE
10k Refrigerant amount : 0.52kg
13k Refrigerant amount : 0.58kg
NOTE :
Max.
: 15m
Min.
: 2m
Chargeless : 15m
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)