In network 7 of FC300 we move a value of 1 into DB301.DBB0 this is the target address of the WSB
which we set earlier using *66 in the WSB Controller you may wish to change this value for clarity in
a multiple blender application just makes sure whatever you set the value to using *66 then move
the same value into DB301.DBB0.
Note:
If you send commands with the Anybus Gateway with a node number of 00 this will be seen as a
global broadcast so in a multi-dropped environment this will change all blenders to the settings sent.

WSB (MLAN) Commands Programmed In Gateway

Figure 19: MLAN Commands In Gateway

Figure 19 shows the pre-programmed list of commands that are in the Anybus gateway. A full list of
commands can be found at
following section of the manual we will look at a command in depth and how the PLC and gateway
handles the command.
The command we shall be looking at is Get Settings (20). The following is an extract from the
Maguire MLAN protocol manual Edition: March 11, 2014:
Ref: S7-1200-12-12-WSB
http://www.maguire.com/ps_image/pdf/mlan-protocol.pdf