Siemens S7-1200 Manual page 21

Gateway to maguire 12-12 weigh scale blender
Hide thumbs Also See for S7-1200:
Table of Contents

Advertisement

Field #
Name
20
Setting Hopper 8
21
Type Hopper 9
22
Setting Hopper 9
23
Type Hopper 10 (A)
24
Setting Hopper 10 (A)
25
Type Hopper 11 (B)
26
Setting Hopper 11 (B)
27
Type Hopper 12 (C)
28
Setting Hopper 12 (C)
29
Recipe Number
30
Operator Number
31
Works Order Number
32
Checksum
The response is as shown in figure 20, the response being what we are expecting back from the WSB
Control.
Ref: S7-1200-12-12-WSB
Size
Range
2
0 to 999
1
0 to 3
2
0 to 999
1
0 to 3
2
0 to 999
1
0 to 3
2
0 to 999
1
0 to 3
2
0 to 999
1
100 to 65536
2
0 to 999
1
0 to 999,999
2
0 to 255
Total
49
Berkshire Systemic Solutions Ltd
www.bss-ltd.biz
Siemens S7-1200 interfacing via HMS Anybus Gateway
to Maguire 12-12 Weigh Scale Blender
Description
Implied decimal point ##.#
Always zeros (implied 1=regrind)
Implied decimal point ##.#
Always zeros (implied 1=regrind)
Implied decimal point ##.#
Always zeros (implied 1=regrind)
Implied decimal point ##.#
Always zeros (implied 1=regrind)
Implied decimal point ##.#
Always zeros (implied 1=regrind)
Operator Number
Works Order Number
Checksum
V1.00
Page 21 of 44

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents