Components
Dual surface units:
Right Front(RF)
Element
Test procedures
1. Refer to page 3-7 for the servicing procedure
2. Set the Multiple meter scale to the R x1
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the (E1 & 1A)
and (E2 & 1A) the meter should indicate :
32 Ω ± 10%
- (E1 & 1A)
54 Ω ± 10%
- (E2 & 1A)
5. Touch the ohmmeter test leads to limiter
terminals 1B and 2B.
With the temperature below 150˚F, the meter
should indicate an open circuit(infinite).
With the temperature above 150˚F, the meter
should indicate continuity (0 Ω).
4-10
Results
Normal: Approximately 32 Ω
Normal: Approximately 54 Ω
Below 150˚F
open circuit (infinite).
Above 150˚F
continuity (0 Ω)