CHECKING FLOW CHART BY FAILURE
Plug in the unit
3
Is the value of thermistor
normal? (Refer below)
Check with the test mode
To enter the test mode, follow these steps:
1. Press the any button, and encoder is placed
in the Off
2. Press the button in the following order
: + → → _ → → Oven light
(Oven Light hold for 3 seconds).
3. Press the OVEN LIGHT button again.
(hold for 3seconds)
4. Select the "t3" by press the + button
5. Press the START button
Normal : Thermistor value at room temp is from
70˚F to 90
F
˚
4
Replace the Main PCB.
Yes
Replace the
Relay PCB
No
9-14