NMS login example

The configuration example was created on the 10500/7500 20G unified wired-WLAN module and
might vary with device models.
When configuring the 10500/7500 20G unified wired-WLAN module, make sure the settings are
correct (including VLAN settings) on the internal Ethernet interface that connects the module to the switch.
For more information, see HP 10500/7500 20G Unified Wired-WLAN Module Fundamentals
Configuration Guide.
By default, the aggregate interfaces between the access controller engine and the switching engine on
an 830 switch are Access interfaces in VLAN 1. When configuring the two aggregate interfaces, make
sure their permitted VLANs are the same. HP also recommends setting their link type to be the same.

Network requirements

Configure the AC and NMS so you can remotely manage the AC through SNMPv3.
Figure 19 Network diagram

Configuration procedure

1.
Configure the AC:
# Assign an IP address to the AC. Make sure the AC and the NMS can reach each other. (Details
not shown.)
# Enter system view.
<AC> system-view
# Enable the SNMP agent.
[AC] snmp-agent
# Configure an SNMP group.
[AC] snmp-agent group v3 managev3group
# Add a user to the SNMP group.
[AC] snmp-agent usm-user v3 managev3user managev3group
2.
Configure the NMS:
Make sure the NMS has the same SNMP settings, including the username, as the device. If not, the
device cannot be discovered or managed by the NMS.
3.
Use the network management station to discover, query, and configure the device. For more
information, see the NMS manual.