Bosch PTD 1 Original Instructions Manual page 16

Thermo detector
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
OBJ_DOKU-31220-002.fm Page 16 Friday, April 11, 2014 10:35 AM
16 | English
The flashing Symbol for ambient temperature e indi-
cates that the room temperature is too low;
The flashing Symbol for surface temperature h indicates
thermal bridges.
When the risk of mould is given, you should – depending on
the cause – reduce the humidity through more frequent and
thorough ventilation, increase the room temperature and
eliminate thermal bridges. If required, refer to a building ex-
pert.
Note: The measuring tool cannot detect mould spores. It only
indicates the possible formation of mould when the condi-
tions remain the same.
Troubleshooting
Causes and Corrective
Measures
All of the following error messages in the display are accom-
panied by the red signal LED 8.
Measuring Tool not Acclimatized
The measuring tool was exposed
to severe variations in tempera-
ture and did not have enough time
to adapt.
The measuring tool switches off
automatically after 5 seconds.
Wait approx. 10 to 30 minutes until the measuring tool has
adapted to the current temperatures. The acclimatization is
accelerated when the measuring tool is periodically moved
around in the room.
Ambient Temperature not in Operating-temperature
Range
The ambient temperature is too
high or too low for operation of the
measuring tool. The measuring
tool switches off after 5 seconds;
taking measurements in this envi-
ronment is not possible.
Surface Temperature not within the Measuring Range
The surface temperature of the object in the laser circle is too
high ("Hi") or too low ("Lo"). The temperature of this object
cannot be measured. Point the laser circle to another object
and start a new measurement.
Internal Error
The measuring tool has an internal
error and switches off after 5 sec-
onds.
To reset the software, remove the
batteries, wait a few seconds and
then insert the batteries again.
1 609 92A 0K5 | (11.4.14)
If the error continues, have the measuring tool checked by an
authorised Bosch after-sales service.
Definitions
Emissivity Degree
The emissivity degree of an object depends on the material
and the structure of its surface. It indicates whether an object
(in comparison with other objects with the same tempera-
ture) emits much or little infrared heat radiation.
Thermal Bridge
A thermal bridge is defined as an object that undesirably
transmits heat from one side to the other.
As the surface temperature at thermal bridges is lower than in
the rest of the room, the risk of mould increases significantly
at these locations.
Relative Humidity
The relative humidity provides information on how intensive
the air is saturated with water vapour. It is stated as a percent-
age of the maximum amount of water vapour that the air can
absorb. The maximum amount of water vapour depends on
the temperature: The higher the temperature, the more
amount of water vapour the air can absorb.
When the relative humidity is too high, the risk of mould in-
creases. Too low humidity can lead to health impairments.
Dew Point Temperature
The dew point temperature indicates the temperature at
which the water vapour in the air starts to condense. The dew
point temperature depends on the relative humidity and the
air temperature.
When the temperature of a surface is below the dew point
temperature, water begins to condense on this surface. The
larger the difference of both temperatures and the higher the
relative humidity, the greater the condensation.
Condensate on surfaces is a major cause for the formation of
mould.
Maintenance and Service
Maintenance and Cleaning
Store and transport the measuring tool only in the supplied
protective pouch 16. Do not, as an example, store the meas-
uring tool in a plastic bag, as the evaporation could damage
the humidity and temperature sensor 1. Do not attach stick-
ers onto the measuring tool close to the sensor.
Do not store the measuring tool for long periods out of a hu-
midity range between 30 to 50 %. When the measuring tool is
stored too moist or too dry, faulty measurements can occur
when starting operation.
Keep the measuring tool clean at all times.
Wipe off debris using a moist and soft cloth. Do not use any
cleaning agents or solvents.
When cleaning, fluids should not penetrate into the measur-
ing tool.
Bosch Power Tools