6.1.1.4

Mounting

Note
The motor reactor must be mounted as close as possible to the Power Module.
Installation of motor reactors for PM240-2 Power Modules
The motor reactors for PM240-2 Power Modules of frame sizes FSA to FSC are designed for
installation in a cabinet. The motor reactor is installed on the mounting surface next to the
Power Module.
Table 6- 6
Mounting of motor reactors for PM240-2 Power Modules
Frame size
FSA
FSB
FSC
AC Drive
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
Fastening
4 x M4 screws
4 x M4 nuts
4 x M4 washers
4 x M5 screws
4 x M5 nuts
4 x M5 washers
Motor-side power components
Tightening torque
3 Nm
5 Nm
6.1 Blocksize
221