Technical Data - Siemens S120 Manual

Hide thumbs Also See for S120:
Table of Contents

Advertisement

Motor-side power components
6.1 Blocksize
6.1.1.6

Technical data

Table 6- 13
Motor reactors for PM240-2 Power Modules, frame size FSA to FSC
Order No. 6SL3202-
Frame size
Matching Power
Modules
1)
Inductance
Rated current
Power loss
Degree of protection
Weight
x = A: Power Module with integrated line filter, x = U: Power Module without integrated line filter
1)
228
0AE16-1CA0
FSA (2.2 kW)
Line voltage 1-phase 200 VAC -10% to 240 VAC +10%:
6SL3210-
1PB13-0xL0
1PB13-8xL0
1PB15-5xL0
6SL3211-
1PB13-8xL0
Line voltage 3-phase 380 VAC -10% to 480 VAC +10%:
6SL3210-
1PE11-8xL1
1PE12-3xL1
1PE13-2xL1
1PE14-3xL1
1PE16-1xL1
mH
2,5
A
6,1
kW
0,09
IP20
kg
3,4
0AE18-8CA0
0AE21-8CA0
FSA (4 kW)
FSB (7.5 kW)
6SL3210-
6SL3210-
1PB17-4xL0
1PB21-0xL0
1PB21-4xL0
1PB21-8xL0
6SL3211-
1PB21-0xL0
1PB21-8xL0
6SL3210-
6SL3210-
1PE18-0xL1
1PE21-1xL0
1PE21-4xL0
6SL3211-
1PE21-8xL0
1PE18-0xL1
6SL3211-
1PE21-8xL0
1,3
0,54
9,0
18,5
0,08
0,08
IP20
IP20
3,9
10,1
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
0AE23-8CA0
FSC (18.5 kW)
6SL3210-
1PC22-2xL0
1PC22-8xL0
6SL3211-
1PB22-2xL0
6SL3210-
1PE22-7xL0
1PE23-3xL0
6SL3211-
1PE23-3xL0
0,26
39,0
0,11
IP20
11,2
AC Drive

Advertisement

Table of Contents
loading