Connectable components
9.2 PP 72/48D PN
Name
Activity
PROFINET address (S1)
A logical address can be assigned to the I/O module for communication with PROFINET using
a 10-bit DIP switch S1.
Table 9-19
1
on
The switch positions 9 and 10 guarantee the PROFINET functionality of the module and must
always be switched "on".
DCP mode
In this mode, there is no default device name.
The device name must be set using initialization and remains saved on the I/O module. It is
first deleted when the factory setting is restored, e.g. using STEP7.
Default device names
The switch positions 1 to 8 define the default device name of the I/O module.
There are up to 128 default device names. If these default device names are used, there is no
need for initialization.
Note
The default device names cannot be reconfigured using the STEP7 "device initialization"
facility, for example.
If you are connecting the I/O module to a SINUMERIK controller as a PROFINET component,
make sure that this functionality is supported by the controller concerned.
Table 9-20
1
on
off
on
off
on
off
on
off
104
Color
Status
Orange
lit
off
General settings with switch S1
2
3
4
5
6
on
on
on
on
on
Default device name with switch S1
2
3
4
5
6
on
on
on
on
on
on
on
on
on
on
off
on
on
on
on
off
on
on
on
on
on
off
on
on
on
on
off
on
on
on
off
off
on
on
on
off
off
on
on
on
Meaning
Data exchange
No data exchange
7
8
9
10
Meaning
on
on
PROFINET functionality
on
on
DCP mode
7
8
9
10
Default device name
on
off
pp72x48pn127
on
off
pp72x48pn126
on
off
pp72x48pn125
on
off
pp72x48pn124
on
off
pp72x48pn123
on
off
pp72x48pn122
on
off
pp72x48pn121
on
off
pp72x48pn120
NCU 7x0.3 PN, NCU 7x0.3B PN
Manual, 06/2014, 6FC5397-1EP40-5BA1