Cable
IE FC Trailing Cable GP 2x2
(Type C)
IE FC Trailing Cable 2x2
(Type C)
IE FC Marine Cable 2x2
7.7.3

Preparing the twisted pair cables

Function
The IE FC RJ45 Plugs are used to install uncrossed 100 Mbit/s Ethernet connections up to
100 m without the use of patches. Crossed cables can also be installed by swapping the
transmit and receive pair in a plug.
Prerequisite
When you set up your PROFINET system, you can cut the AWG 22 twisted pair cable on-site
to the required length, strip it with the
and fit the
Proceed as follows
Contacting of the FC cable versions is simple and reliable with the 4 integrated insulation
displacement contacts.
● When the plug case is open, color markings on the contact cover make it easier to connect
● The stripped end of the cable is inserted in the raised insulation displacement terminals
NCU 7x0.3 PN, NCU 7x0.3B PN
Manual, 06/2014, 6FC5397-1EP40-5BA1
Industrial Ethernet FastConnect RJ-45 Plugs using the cut-and-clamp technique.
the cores to the insulation piercing connecting devices. The user can check that contact
has been made correctly through the transparent plastic material of the contact cover.
and the terminals are then pressed down to ensure reliable contacting of the conductors.
Designation
4-wire TP installation cable for ground cable use 6XV1 870-2D
4-wire shielded TP installation cable for
connection to FC OUTLET RJ45, for ground
cable use
4-wire shielded marine-certified TP installation
cable for connection to FC OUTLET RJ45
Fast Connect Stripping Tool (for Industrial Ethernet),
Connecting
7.7 PROFINET
Order number
6XV1 840-3AH10
6XV1 840-4AH10
61