Fundamental safety instructions
1.4 Residual risks of power drive systems
1. Unintentional movements of driven machine components during commissioning, operation,
2. In the event of a fault, exceptionally high temperatures, including an open fire, as well as
3. Hazardous shock voltages caused by, for example,
4. Electrical, magnetic and electromagnetic fields generated in operation that can pose a risk
5. Release of environmental pollutants or emissions as a result of improper operation of the
Note
The components must be protected against conductive contamination (e.g. by installing them
in a control cabinet with degree of protection IP54 according to IEC 60529 or NEMA 12).
Assuming that conductive contamination at the installation site can definitely be excluded, a
lower degree of cabinet protection may be permitted.
14
maintenance, and repairs caused by, for example,
– Hardware and/or software errors in the sensors, control system, actuators, and cables
and connections
– Response times of the control system and of the drive
– Operation and/or environmental conditions outside the specification
– Condensation/conductive contamination
– Parameterization, programming, cabling, and installation errors
– Use of wireless devices/mobile phones in the immediate vicinity of the control system
– External influences/damage
emissions of light, noise, particles, gases, etc. can occur inside and outside the inverter,
e.g.:
– Component failure
– Software errors
– Operation and/or environmental conditions outside the specification
– External influences/damage
Inverters of the Open Type/IP20 degree of protection must be installed in a metal control
cabinet (or protected by another equivalent measure) such that contact with fire inside and
outside the inverter is not possible.
– Component failure
– Influence during electrostatic charging
– Induction of voltages in moving motors
– Operation and/or environmental conditions outside the specification
– Condensation/conductive contamination
– External influences/damage
to people with a pacemaker, implants or metal replacement joints, etc., if they are too close
system and/or failure to dispose of components safely and correctly