4.3.8 I/O Check

Select 4. I/O on the Program Menu screen. Check to display analog and digital input/output signal status for the drive and
options. Use
and
60.00
RUN
FWD
PRG
PRG > PRG MENU
F/D > LED SHIFT
60.00
Y1
Y5
Y2
Y3
Signal OFF.
Y4
60.00
12=±xx.xV
22=±xx.xV
32=±xx.xV
V2=±xx.xV
60.00
AO=xxxxV
CS=xxxmA
DI=xxxxH
DO=xxH
60.00
P1=±xxxx0p/s
Z1=xxxp/s
P2=±xxxxxOp/s
Z2=xxxp/s
to switch between the seven screens of data.
60.00
1.DATA SETTING
2.DATA CHECK
3. OPR MNTR
> 4.I/O CHECK
Output terminal status
Signal ON
Analog input signal
Terminal 12 input
Terminal 22 input voltage
(AIO option)
Terminal 32 input voltage
(AIO option)
Terminal V2 input
DIO option I/O status
Analog output voltage (AIO option)
Analog output current (AIO option)
Digital input terminal (HEX indication)
Digital ouput terminal (HEX indication)
PG/SY option input status
Master-side A/B phase 4x frequency
Master-side Z phase 4x frequency
Slave-side A/B phase 4x frequency
Slave-side Z phase 4x frequency
60.00
REM
X2
X6
FUNC
DATA
FWD
X3
X7
REV
X4
X8
X1
X5
X9
60.00
COM
X2
X6
FWD
X3
X7
REV
X4
X8
X1
X5
X9
60.00
C1=xx.xmA
C2=xx.xmA
60.00
FMA=xx.xH
FMP=xx.xV
FMP=xxxxp/s
4-8
Data subject to change without notice 7/07. © 2007 GE Drives
Input terminal status (terminals)
Signal OFF.
Signal ON
Input terminal status
(via communication)
Signal OFF.
Signal ON
Analog input signal
Terminal C1 input current
Terminal C2 input current (AIO option)
Output for meter
FMA output voltage
FMP output voltage
FMP output frequency