ERROR CODE DESCRIPTION

CODE
EXPLANATIONS
ER1
Cavity high temperature protection.
ER2
Steam plate high temperature protection.
ER3
Cavity low temperature protection.
ER4
Steam plate low temperature protection.
ER5
Sensor connection failure.
ER6
Sensor sense failure.
Whirlpool Hong Kong Ltd.
17/F., Elite Centre,
22 Hung To Road
Kwun Tong, Kowloon, H.K.
POSSIBLE REASONS
Temperature in cavity exceeds safety setting.
Temperature of steam plate exceeds safety setting.
Continue working for 3 minutes but temperature of cavity
O
is lower than 30
C.
Continue working for 3 minutes but temperature of cavity
O
is lower than 30
C.
Sensor connection failure, causing of open circuit.
Sensor sense failure, causing of short circuit.