2.6.3

Process

Classific
Code
ation
400
Fuser
Fuser unit error status
counter
556
Image
Image quality closed-loop
control
control/Contrast voltage
557
Image
Image quality closed-loop
control
control/Laser power
573
Image
Abnormality detection
control
count (Y)
Display/0 clearing
574
Image
Abnormality detection
control
count (M)
Display/0 clearing
575
Image
Abnormality detection
control
count (C)
Display/0 clearing
© 2008 - 2011 TOSHIBA TEC CORPORATION All rights reserved
Setting mode (08)
Functi
<Accept
Items
on
ALL
ALL
ALL
ALL
ALL
ALL
2 - 91
Default
RAM
Contents
able
value>
0
M
0: No error
<0-51>
1: C411 2: C412
3: C443 4: -
5: C445, C465
6: C446, C466
7: C447 8: C468
9: C449
10 to 17: -
18: C468 19: C449
20: C468 21: C449
22: C449 23: C449
24: C447 25: C449
26: C468 27: C449
28: C468 29: C449
30: -
31: C4D0 32: C448
33: C467 34: C467
35 to 37: -
38: C450 39: C450
40: -
41: C451 42: C451
43: -
44 to 47: -
48: C450 49: C450
50: C452 51: C452
1
M
Sets whether or not
<0-1>
correcting the contrast
voltage in closed-loop
control.
0: Invalid
1: Valid
1
M
Sets whether or not
<0-1>
correcting the laser
power in closed-loop
control.
0: Invalid
1: Valid
0
M
Counts the abnormality
<0-16>
detection of image
quality control.
Accumulating total of
[CE10], [CE20] and
[CE40]
0
M
Counts the abnormality
<0-16>
detection of image
quality control.
Accumulating total of
[CE10], [CE20] and
[CE40]
0
M
Counts the abnormality
<0-16>
detection of image
quality control.
Accumulating total of
[CE10], [CE20] and
[CE40]
e-STUDIO2020C/2330C/2820C/2830C/3520C/3530C/4520C