Making DME GPI Input Settings

The same GPI input is used for switcher processor control and for the MKS-
6470 GPI input.
1
2
3
4
5
1138
Interfacing With External Devices (Device Interface Menu)
In the DME >Device Interface menu, press [DME1 GPI Input].
The DME1 GPI Input menu appears.
Using any of the following methods, select the settings.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knobs.
Knob
Parameter
1
Port
2
No
In the <Trigger Type> group, select the trigger polarity.
(Rising Edge): Apply the trigger on a rising edge of an input pulse.
(Falling Edge): Apply the trigger on a falling edge of an input
pulse.
(Any Edge): Apply the trigger on a change in the polarity of the
input signal.
(Level): Carry out the specified operation when the input is low or
high.
No Operation: Apply no trigger on an input pulse.
In the <Target> group, select what this applies to (channels 1 to 4, or Proc).
Using any of the following methods, select the action to be set.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knobs.
Knob
Parameter
3
Action
4
Reg No
a) As for the setting values, see "Selectable actions for various trigger types" (page 1139).
b) When knob 3 selection is "Snapshot"
Adjustment
Input port selection
Selection of number for action to
be assigned
Adjustment
Action selection
Register number
Setting values
1 to 8
1 to 8
Setting values
a)
1 and upwards
b)
1 to 99
c)
1 to 399