Issue 10/06
Holding brake
Series / commissioning for hazardous loads
− lower the load to the floor
− when replacing the frequency inverter, prevent (inhibit) the frequency
inverter from controlling the motor holding brake (MHB)
− secure the load or inhibit the motor holding brake control (so that the brake
cannot be controlled) and then – and only then – carry-out quick
commissioning / parameter download using the PC-based tool (e.g.
STARTER, AOP)
Parameterize the weight equalization for hoisting gear applications
− magnetizing time P0346 greater than zero
− min. frequency P1080 should approximately correspond to the motor slip
r0330 (P1080 ≈ r0330)
− adapt the voltage boost to the load
a) V/f (P1300 = 0 ...3):
b) SLVC (P1300 =20):
It is not sufficient to just select the status signal r0052 bit 12 "motor holding
brake active" in P0731 – P0733. In order to activate the motor holding brake, in
addition, parameter P1215 must be set to 1.
It is not permissible to use the motor holding brake as operating brake. The
reason for this is that the brake is generally only dimensioned/designed for a
limited number of emergency braking operations.
The brake closing / opening times can be taken from the appropriate manual.
The following typical values have been taken from Motor Catalog M11
2003/2004, Page 2/51:
Motor size
63
71
80
90
100
112
132
160
180
200
225
Holding brake enable
P1215 =...
Enables/disables holding brake function (MHB).
0
Motor holding brake disabled
1
Motor holding brake enabled
NOTE
The following must apply when controlling the brake relay via a digital output: P0731 = 52.C (= 52.12)
(refer to Section 3.5.7.4 "Digital output (DOUT)").
MICROMASTER 440
Operating Instructions
6SE6400-5AW00-0BP0
P1310, P1311
P1610, P1611
Brake type
Opening time [ms]
2LM8 005-1NAxx
2LM8 005-2NAxx
2LM8 010-3NAxx
2LM8 020-4NAxx
2LM8 040-5NAxx
2LM8 060-6NAxx
2LM8 100-7NAxx
2LM8 260-8NAxx
2LM8 315-0NAxx
2LM8 400-0NAxx
3 Functions
Closing time [ms]
25
56
25
56
26
70
37
90
43
140
60
210
50
270
165
340
152
410
230
390
0
119