When data are written to D13 and D14 from a GOT touch switch, for example, the data of D13
and D14 are transmitted (interrupt output) to the host side.
The data amount (number of bytes) to be interrupt-output is set at "Interrupt Data Byte" in
"Communication Detail Settings".(
settings))
D13
• Output value when 1 is set to "Interrupt Data Byte" in "Communication Detail Settings"
D13
Lower 8 bits
1 byte
• Output value when 2 is set to "Interrupt Data Byte" in "Communication Detail Settings"
Upper 8 bits
• Output value when 4 is set to "Interrupt Data Byte" in "Communication Detail Settings
"(1) When setting the LH order to [32bit Storage] for the communication detail settings
D14
Upper 8 bits
(2) When setting the HL order to [32bit Storage] for the communication detail settings
Upper 8 bits
D15 to 19
D20 to 2031
D2032 to 2034
1-second binary counter
The counter is incremented at 1-second intervals after the GOT is turned ON.
D2035
(The time elapsed after GOT is turned ON is stored in 1-second units.)
Data are stored in binary format.
D2036 to 4095
D20 to 511
*1
After writing data, the interrupt data is output within a period of 1 to 10ms.
*2
When data are written to D13 and D14 from the host side, interrupt output is not performed.
Description
2.6.1 Setting communication interface (Communication
D13
Lower 8 bits
2 bytes
D14
Lower 8 bits
Upper 8 bits
4 bytes
D13
Lower 8 bits
Upper 8 bits
4 bytes
Unused
User area
Unused
User area
User area
2. MICROCOMPUTER CONNECTION (SERIAL)
(From previous page)
*1*2
D13
Lower 8 bits
D14
Lower 8 bits
2.4 Device Data Area
1
Set side
2
3
User
4
5
6
User
System
User
7
User
8
2 - 13