8. Strip3/8(9.53mm)inches of insulation f romtheendof thewire.
3/8 "
Figure 16: Wire Stripping
9.
Insert the insulated grounding wire into the lug below the terminal block.
10. Insert stripped end of white wire into the center lug. Secure the clamping-
screw.
..-JJ
lug
. - _'Y
wire
clamping
screw
Figure 17: Attaching Wire to Lug
11. Insert stripped end of red wire into the left lug. Secure clamping screw.
12. Insert black wire into the right lug. Secure clamping screw. Tighten each
clamping screw with the appropriate torque (see table).
Table 3: Appropriate Torque Levels for Aluminum or Copper Wire
Gauge
Torque (in./Ibs.)
Torque (Nm)
6
35
3.95
8
25
2.82
13. Properly secure flexible conduit at knockout on angle and at supply side junc-
......................................
t!°
bo
Thew!r!ng!
no
comp!e!
................................................................................
\
red wire
black wire
white wire
green ground
wire
Figure 18: Completed Four Wire Flexible Conduit Connection
English 13

Advertisement