MODBUS MEMORY MAP
Address
Description
7145
Ground Distance Zone 1 Non-Homogeneous Angle
7146
Ground Distance Zone 1 POL Current
7147
Ground Distance Zone 1 Reverse Reach
7148
Ground Distance Zone 1 Reverse Reach RCA
7149
Reserved (7 items)
7150
...Repeated for Ground Distance Zone 2
7170
...Repeated for Ground Distance Zone 3
7190
...Repeated for Ground Distance Zone 4
71B0
...Repeated for Ground Distance Zone 5
Line Pickup (Read/Write Grouped Setting)
71F0
Line Pickup Function
71F1
Line Pickup Signal Source
71F2
Line Pickup Phase IOC Pickup
71F3
Line Pickup UV Pickup
71F4
Line End Open Pickup Delay
71F5
Line End Open Reset Delay
71F6
Line Pickup OV Pickup Delay
71F7
Autoreclose Coordination Pickup Delay
71F8
Autoreclose Coordination Reset Delay
71F9
Autoreclose Coordination Bypass
71FA
Line Pickup Block
71FC
Line Pickup Events
71FD
Terminal Open
71FE
Autoreclose Accelerate
71FF
Line Pickup Distance Trip
Breaker Failure (Read/Write Grouped Setting) (2 Modules)
7200
Breaker Failure 1 Function
7201
Breaker Failure 1 Mode
7208
Breaker Failure 1 Source
7209
Breaker Failure 1 Amp Supervision
720A
Breaker Failure 1 Use Seal-In
720B
Breaker Failure 1 Three Pole Initiate
720C
Breaker Failure 1 Block
720D
Breaker Failure 1 Phase Amp Supv Pickup
720E
Breaker Failure 1 Neutral Amp Supv Pickup
720F
Breaker Failure 1 Use Timer 1
7210
Breaker Failure 1 Timer 1 Pickup
7211
Breaker Failure 1 Use Timer 2
7212
Breaker Failure 1 Timer 2 Pickup
7213
Breaker Failure 1 Use Timer 3
7214
Breaker Failure 1 Timer 3 Pickup
7215
Breaker Failure 1 Breaker Status 1 Phase A/3P
7216
Breaker Failure 1 Breaker Status 2 Phase A/3P
7217
Breaker Failure 1 Breaker Test On
7218
Breaker Failure 1 Phase Amp Hiset Pickup
7219
Breaker Failure 1 Neutral Amp Hiset Pickup
721A
Breaker Failure 1 Phase Amp Loset Pickup
96
Range
Units
-40 to 40
degrees 0.1
0 to 1
---
0.02 to 500
ohms
30 to 90
degrees 1
0 to 65535
---
0 to 1
---
0 to 5
---
0 to 30
pu
0 to 3
pu
0 to 65.535
s
0 to 65.535
s
0 to 65.535
s
0 to 65.535
s
0 to 65.535
s
0 to 1
---
0 to 65535
---
0 to 1
---
0 to 65535
---
0 to 65535
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 5
---
0 to 1
---
0 to 1
---
0 to 65535
---
0 to 65535
---
0.001 to 30
pu
0.001 to 30
pu
0 to 1
---
0 to 65.535
s
0 to 1
---
0 to 65.535
s
0 to 1
---
0 to 65.535
s
0 to 65535
---
0 to 65535
---
0 to 65535
---
0.001 to 30
pu
0.001 to 30
pu
0.001 to 30
pu
PLUS
D90
LINE DISTANCE PROTECTION SYSTEM – COMMUNICATIONS GUIDE
CHAPTER 2: MODBUS COMMUNICATION
Step
Format
Default
F002
0
1
F521
0 (Zero-seq)
0.01
F001
200
F001
85
1
F001
0
1
F102
0 (Disabled)
1
F167
0 (SRC 1)
0.001
F001
1000
0.001
F001
700
0.001
F001
150
0.001
F001
90
0.001
F001
40
0.001
F001
45
0.001
F001
5
1
F102
1 (Enabled)
1
F300
0
1
F102
0 (Disabled)
1
F300
0
1
F300
0
1
F102
1 (Enabled)
1
F102
0 (Disabled)
1
F157
0 (3-Pole)
1
F167
0 (SRC 1)
1
F126
1 (Yes)
1
F126
1 (Yes)
1
F300
0
1
F300
0
0.001
F001
1050
0.001
F001
1050
1
F126
1 (Yes)
0.001
F001
0
1
F126
1 (Yes)
0.001
F001
0
1
F126
1 (Yes)
0.001
F001
0
1
F300
0
1
F300
0
1
F300
0
0.001
F001
1050
0.001
F001
1050
0.001
F001
1050