MODBUS MEMORY MAP
Address
Description
1C2E
Source 2 Phase C Reactive Power
1C30
Source 2 Three-Phase Apparent Power
1C32
Source 2 Phase A Apparent Power
1C34
Source 2 Phase B Apparent Power
1C36
Source 2 Phase C Apparent Power
1C38
Source 2 Three-Phase Power Factor
1C39
Source 2 Phase A Power Factor
1C3A
Source 2 Phase B Power Factor
1C3B
Source 2 Phase C Power Factor
1C40
Source 3 Three-Phase Real Power
1C42
Source 3 Phase A Real Power
1C44
Source 3 Phase B Real Power
1C46
Source 3 Phase C Real Power
1C48
Source 3 Three-Phase Reactive Power
1C4A
Source 3 Phase A Reactive Power
1C4C
Source 3 Phase B Reactive Power
1C4E
Source 3 Phase C Reactive Power
1C50
Source 3 Three-Phase Apparent Power
1C52
Source 3 Phase A Apparent Power
1C54
Source 3 Phase B Apparent Power
1C56
Source 3 Phase C Apparent Power
1C58
Source 3 Three-Phase Power Factor
1C59
Source 3 Phase A Power Factor
1C5A
Source 3 Phase B Power Factor
1C5B
Source 3 Phase C Power Factor
1C60
Source 4 Three-Phase Real Power
1C62
Source 4 Phase A Real Power
1C64
Source 4 Phase B Real Power
1C66
Source 4 Phase C Real Power
1C68
Source 4 Three-Phase Reactive Power
1C6A
Source 4 Phase A Reactive Power
52
Range
Units
-1000000000000 to
var
1000000000000
-1000000000000 to
VA
1000000000000
-1000000000000 to
VA
1000000000000
-1000000000000 to
VA
1000000000000
-1000000000000 to
VA
1000000000000
-0.999 to 1
---
-0.999 to 1
---
-0.999 to 1
---
-0.999 to 1
---
-1000000000000 to
W
1000000000000
-1000000000000 to
W
1000000000000
-1000000000000 to
W
1000000000000
-1000000000000 to
W
1000000000000
-1000000000000 to
var
1000000000000
-1000000000000 to
var
1000000000000
-1000000000000 to
var
1000000000000
-1000000000000 to
var
1000000000000
-1000000000000 to
VA
1000000000000
-1000000000000 to
VA
1000000000000
-1000000000000 to
VA
1000000000000
-1000000000000 to
VA
1000000000000
-0.999 to 1
---
-0.999 to 1
---
-0.999 to 1
---
-0.999 to 1
---
-1000000000000 to
W
1000000000000
-1000000000000 to
W
1000000000000
-1000000000000 to
W
1000000000000
-1000000000000 to
W
1000000000000
-1000000000000 to
var
1000000000000
-1000000000000 to
var
1000000000000
PLUS
D90
LINE DISTANCE PROTECTION SYSTEM – COMMUNICATIONS GUIDE
CHAPTER 2: MODBUS COMMUNICATION
Step
Format
Default
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F013
0
0.001
F013
0
0.001
F013
0
0.001
F013
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F013
0
0.001
F013
0
0.001
F013
0
0.001
F013
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0