To trigger after all status bus lines finish transitioning

In some applications, you will want to trigger a measurement when a
particular pattern has become stable. For example, you might want to trigger
the analyzer when a microprocessor's status bus has become stable during
the bus cycle.
Select the timing analyzer Trigger menu and define a term called
1
PATTERN to represent the value to be found on the label
representing the status bus lines.
Under Timing Sequence Levels, enter the following sequence
2
specification:
TRIGGER on "PATTERN" > 40 ns
To trigger after all status bus lines finish transitioning
Triggering
115