Siemens SIMATIC Ident System Manual page 189

Identification rfid systems
Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Permitted ambient conditions
Ambient temperature
Degree of protection to EN 60529
Shock-resistant to EN 60721-3-7, Class 7 M3
Vibration-resistant to EN 60721-3-7, Class 7 M3
Torsion and bending load
Design, dimensions and weight
Dimensions (L x W x H)
Weight
Type of mounting
Cable length for RS-422 interface, maximum
LED display design
Standards, specifications, approvals
Proof of suitability
5.8.10
Approvals
FCC information
Siemens SIMATIC RF382R (MLFB 6GT2801-3AB20-0AX0); FCC ID NXW-RF382R
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Caution
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
During operation
During transportation and storage
5.8 SIMATIC RF382R with Scanmode
-25 to +70 ℃
-40 to +85 ℃
IP67
50 g
20 g
Not permitted
160 x 80 x 41 mm
550 g
4 x M5 screws;
1.5 Nm
RS-422
1000 m
3-color LED
Radio to R&TTE directives EN 300330,
EN 301489, CE, FCC, UL/CSA
Readers
6GT2801-3AB20-0AX0
RS-232
30 m
189